pasiūlyti gerą pasiūlymą
Clemco's CPF in-line air filters remove moisture, oil, and dirt particles from compressed air before it reaches your respirator. Multi-stage filtration system includes activated charcoal to eliminate odors and improve the "taste" of your breathing air. Available for one to four air lines; used with HP Model respirators.
Model CPF-20 for up to two operators
Model CPF-80 for up to four operators
Description of Operation
The CPF filter is placed in the breathing-air line between the breathing-air source and the respirator supply hose. The CPF is the point of attachment for the respirator hose. Air enters the filter through one of the inlet ports. Moisture is removed by expansion in the outer chamber and is drained through a petcock at the bottom of the unit. The air passes through a replaceable filter cartridge. The outlet pressure is controlled by a regulator on the cap and is measured by a gauge downstream from the cartridge.