pasiūlyti gerą pasiūlymą
The Elcometer 456 dry film thickness gauge is available in three different models. Each coating thickness gauge provides the user with increasing functionality - from the entry level Elcometer 456 Model B, to the top of the range Elcometer 456 Model T.
Separate coating thickness gauge models, with their wide range of probes, provide even greater dry film thickness measurement flexibility.
Compatible with ElcoMaster® software and ElcoMaster® Mobile App, individual coating thickness measurements can be transferred via USB or Bluetooth® to PC or a mobile device for analysis and instant report generation.
Separate Model Options |
|
|
|
|
|||||
|
Model B |
Model S |
Model T |
C |
|||||
Elcometer 456 Ferrous Separate |
A456CFBS |
A456CFSS |
A456CFTS |
● |
|||||
Elcometer 456 Non-Ferrous Separate |
A456CNBS |
A456CNSS |
A456CNTS |
● |
|||||
Elcometer 456 Dual FNF Separate |
A456CFNFBS |
A456CFNFSS |
A456CFNFTS |
● |
|||||
Probes are supplied separately |
Technical Specification |
|
Display information |
2.4" (6cm) QVGA colour TFT display, 320 x 240 pixels |
Battery type |
2 x AA dry cell batteries, rechargeable batteries can also be used |
Battery life |
~24 hours of continuous use at 1 reading per second5 |
Gauge dimensions (h x w x d) |
141 x 73 x 37mm (5.55 x 2.87 x 1.46") |
Gauge weight |
161g (5.68oz) including supplied batteries |
Operating temperature |
-10 to 50°C (14 to 122°F) |
Packing List |
Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T), 1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMaster® software (S, T) |
Elcometer 456 Coating Thickness Gauge Probe Range Explained
Straight Probes
Measure coating thickness on both flat and curved surfaces
Mini Probes
Ideal for measuring coating thickness on edges, narrow pipes or small surface areas
Right Angle Probes
Designed for taking coating thickness readings where access is restricted
PINIP™ Probes
Plug-in probes convert a separate coating thickness gauge into an integral gauge
Telescopic Probes
Extending right angle probes for out of reach areas
These probes are fitted with replaceable probe caps - allowing users to take individual coating thickness measurements or scan large surface areas without damaging the probe
Waterproof Probes
Sealed for use underwater at depth, even in diving gloves
High Temperature Probes
For use on hot coated materials up to 250°C (480°F)
Anodiser Probes
Chemical resistant washable probes - ideal for the anodising environment
Armoured Probes
Probes with metal reinforced heavy duty cables, reducing the risk of cable damage
Soft Coating Probes
Large surface area probes for soft reach materials (HVCA approved)
Specialist Probes
These probes are designed for measuring coating thickness on specialist substrates, such as graphite, or electroplated components
Elcometer probes have a maximum operating temperature of 80°C (176°F) with the exception of separate ferrous probes 150°C (300°F) and Hi-Temperature PINIP’s 250°C (480°F). The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
All Elcometer coating thickness gauge probes are supplied with a Test Certificate and a set of calibration foilsappropriate to the scale range of the probe.